In June 2011, Melbourne’s ‘it’ restaurant, Vue de Monde, relocated to its new location – Level 55 of the iconic Rialto Towers, in place of the former Observation Deck.
A.G. Coombs was appointed Mechanical Engineer & Contractor by project managers Equiset, on behalf of Grollo Australia, and was responsible for the full design and construction of the restaurant’s new air conditioning and ventilation systems.
The new systems were designed from scratch and purpose-built to accommodate both the restaurant’s aesthetic appeal and the existing plant room’s space limitations, sitting just one floor above the diners on Level 56.
A key challenge was the open kitchen with its ventilated ceiling; a fairly new concept in Australia at this time. The ceiling distributes exhaust air and supply air, without obstructing the patrons’ view of the chefs at work. For ease of maintenance, each ceiling tile is demountable for an easy clean in the dishwasher. The open kitchen design also avoids any risk of large quantities of makeup air streaming over the counters and into the cooking areas.
Specific temperature and humidity levels were also critical to design. The spectacular wine cellar features floor-to-ceiling glass that requires a temperature setting of less than 18 degrees Celsius and humidity settings of above 60%, and the dedicated food preparation kitchen in the basement retains low temperature control of below 15 degrees Celsius.
Installation works also proved challenging, with rooftop chillers having to be sized to suit the lifting capacity of the Building Maintenance Unit.
Project Name: Vue de Monde
Location: VIC
Client: Grollo Australia
Project Value: $850k
Year Completed: 2011
Design & Construct – existing building

August 27, 2026 in News
Moisture remains one of the most persistent and challenging risks affecting building performance, indoor environmental quality and asset outcomes, par...

August 27, 2026 in Advisory Notes
External air quality degradation has emerged as a major operational concern for Australian buildings and the issue is expected to intensify as the cli...

August 20, 2026 in News
When Walker Fire Protection was tasked with upgrading the fire sprinkler system at Melbourne’s heritage-listed Town Hall, the project presented ...

August 19, 2026 in News
A.G. Coombs Group was proud to play a significant role in FM Connect 26, the Facility Management Association of Australia's (FMA) premier national con...